Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38523052

RESUMO

BACKGROUND: Patient satisfaction in relation with nursing care has become a key determinant of the quality of hospital care. OBJECTIVES: To evaluate patient satisfaction in relation with nursing care in a critical care context; to determine the correlation between critical patient satisfaction and sociodemographic and clinical variables and to describe patient perceptions with nursing care. METHODS: A descriptive, prospective, correlational study which includes the analysis of some open questions in the intensive care unit (ICU) of a tertiary level university hospital. The degree of satisfaction of all patients discharged from de ICU was evaluated. It was used the validated Spanish version of Nursing Intensive-Care Satisfaction-Scale (NICSS). There were also collected sociodemographic and clinical data and 3 open questions were asked. It was used the inferential and descriptive statistics considering statistically significant p<.05. Open questions were examined using a language context analysis. The approval of the hospital ethical committee was obtained. RESULTS: 111 patients agreed to participate, with a mean age of 64.18 years (CI 95% 61.36-66.88) and with a medium level of satisfaction of 5.83 (CI 95% 5.78-5.88) being 6 the maximum score. Women, older patients and those who reflect a higher degree of recovery, are those who reported greater satisfaction. Three main themes emerged from the analysis of the open-ended questions of the surveys: nurse patient relationship, professional practice environment and ICU nature. CONCLUSION: Patient satisfaction in relation with nursing care was elevated. Age, sex and degree of recovery significantly influenced their perception. Nurse patient relationship and the professional practice environment were aspects highlighted by patients. The professional model incorporated by the institution may encouraged these results.

4.
Rev Esp Quimioter ; 36(5): 516-518, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37265449

RESUMO

During the multiple waves of COVID-19 suffered all over the world, having a rapid and sensitive diagnostic test has become a priority for microbiology laboratories. The AptimaTM SARS-CoV-2 transcription-mediated amplification (TMA) assay running on the Panther system (Hologic) was presented as a very good option to cover this need. To evaluate this system, 570 respiratory samples were included in the study and were processed both by the Panther (Hologic) system and by qRT-PCR (Thermo Fisher Science, Waltham, USA), current assay for the diagnosis of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). A high number of false positives (n=76) was obtained with Panther system (Hologic), but the number of false positives decreases as the relative light units (RLU) value increases. These results show that this technique can be a good option for sample screening but checking for positive results should be mandatory, especially those with low RLU values.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , Teste para COVID-19 , Técnicas de Laboratório Clínico/métodos , Reação em Cadeia da Polimerase , Sensibilidade e Especificidade
5.
Rev Esp Quimioter ; 35(6): 538-543, 2022 Dec.
Artigo em Espanhol | MEDLINE | ID: mdl-36164855

RESUMO

OBJECTIVE: Serological tests have been a valuable tool during the SARS-CoV-2 pandemic, supporting molecular methods for detection, and monitoring the immune response, caused by vaccination or by natural infection. Within all these techniques, rapid tests are interesting due to their ease of use, rapid response and low cost. METHODS: Two different immunological techniques were evaluated: Realy Tech and Mikrogen Diagnostik recomLine SARS-CoV-2 IgG. SARS-CoV-2 IgG II Quant antibody test and SARS-CoV-IgG assay, both from Abbott Diagnostics, were used as reference techniques. RESULTS: Mikrogen Diagnostik recomLine SARS-CoV-2 IgG shows the best results (S=0.985; E=0.839). Three techniques offered good positive predictive values, but Realy Tech and Healgen negative predictive values left to be desired. CONCLUSIONS: Mikrogen Diagnostik recomLine SARS-CoV-2 IgG showed good results in the detection of antibodies against SARS-CoV-2 and could be used as an alternative to automated techniques.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , Teste para COVID-19 , COVID-19/diagnóstico , Sensibilidade e Especificidade , Anticorpos Antivirais , Imunoglobulina G
6.
J Matern Fetal Neonatal Med ; 35(25): 8097-8102, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34470130

RESUMO

BACKGROUND: To describe the brain Doppler changes in fetuses with isolated open spina bifida (OSB). STUDY DESIGN: Doppler ultrasound measurements including the umbilical artery (UA) pulsatility index (PI), middle cerebral artery (MCA) PI, and their combination into the cerebroplacental ratio (CPR) and umbilicocerebral ratio (UCR) were performed in a cohort of fetuses with OSB. Included patients were individually matched to a control group without structural anomalies and similar gestational ages. MCA-PI and/or CPR values below the 5th centile were considered abnormal and indicative of cerebral blood redistribution, while UCR and UA-PI above the 95th centile were considered abnormal. RESULTS: During the study period, 266 fetuses were recruited, 133 normally grown fetuses with OSB and 133 matched controls. Doppler recordings were successfully obtained in all fetuses at a median gestational age of 30.9 weeks. All cases showed UA-PI within normal ranges, but fetuses with OSB showed significantly higher frequency of cerebral blood redistribution (15.0 vs. 3.0%, p < .01), MCA-PI <5th centile (10.5% vs. 3.0%, p = .01), decreased CPR (9.8% vs. 2.3%, p = .01) and increased UCR (17.2 % vs 7.5 %, p =.02). The rate of cerebral blood redistribution was significantly higher in the OSB group with ventriculomegaly in comparison to those with OSB and normal lateral ventricle diameter (18.6% vs. 3.2%, respectively; p <.05). CONCLUSION: A proportion of fetuses with isolated open spina bifida showed cerebral blood redistribution.


Assuntos
Espinha Bífida Cística , Gravidez , Feminino , Humanos , Lactente , Espinha Bífida Cística/diagnóstico por imagem , Ultrassonografia Pré-Natal , Retardo do Crescimento Fetal , Artérias Umbilicais/diagnóstico por imagem , Ultrassonografia Doppler , Feto/diagnóstico por imagem , Feto/irrigação sanguínea , Artéria Cerebral Média/diagnóstico por imagem , Idade Gestacional , Encéfalo , Fluxo Pulsátil
7.
J Virol Methods ; 298: 114281, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34530011

RESUMO

The rapid spread of SARS-CoV-2 led to the necessity of developing diagnostic tests for rapid virus detection. Many commercial platforms have appeared and have been approved for this purpose. In this study, 95 positive and 5 negative retrospective samples were analyzed by 4 different commercial RT-qPCR kits (TaqMan 2019nCoV Assay, Allplex™SARS-COV-2 Assay, FTD SARS-COV-2 Assay and qCOVID-19). The Hologic Aptima SARS-COV-2 and the Clart-COVID-19 system were also tested. serial dilutions of SARS-COV-2 standard control were included for sensitivity analysis. Among the qPCR tested qCOVID19 and Allplex™SARS-COV-2 Assay were both able to detect all the clinical samples included in the study. All four qPCR evaluated showed high sensitivity for samples with Ct<33. Clart-COVID-19 microarrays detected all samples and controls used in this study whereas Hologic Aptima Panther failed with one of the clinical samples. However, the main problem with this system was the number of invalidated samples despite avoiding the use of medium with guanidine isothiocyanate as recommended by the manufacturer. All the techniques tested were of value for SARS-CoV-2 detection.


Assuntos
COVID-19 , SARS-CoV-2 , Teste para COVID-19 , Humanos , RNA Viral/genética , Estudos Retrospectivos , Sensibilidade e Especificidade
10.
Ultrasound Obstet Gynecol ; 58(2): 238-244, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-32798234

RESUMO

OBJECTIVE: To describe changes in fetal Doppler parameters during a novel technique for open fetal microneurosurgery for open spina bifida (OSB) repair. METHODS: This was a prospective study of 44 fetuses undergoing open fetal surgery for OSB repair using a novel microneurosurgery approach that is characterized by a mini-hysterotomy (diameter of 15 mm), minimal fetal manipulation and maintenance of a constant normal amniotic fluid volume throughout the procedure. Doppler velocimetry of the umbilical artery (UA), fetal middle cerebral artery (MCA) and ductus venosus (DV) was performed before the start of surgery and at prespecified timepoints during fetal surgery. UA pulsatility index (PI) > 95th percentile, DV-PI > 95th percentile, MCA-PI < 5th percentile and cerebroplacental ratio (CPR) < 5th percentile were considered abnormal. RESULTS: Median gestational age at fetal surgery was 25.2 weeks (range, 22.9-27.9 weeks). Doppler recordings were successfully obtained in all cases during all timepoints throughout the surgery. As compared with Doppler values before surgery, there was a significant increase in the proportion of fetuses with MCA-PI < 5th percentile (63.6% vs 13.6%; P < 0.001), CPR < 5th percentile (65.9% vs 15.9%; P < 0.001) and DV-PI > 95th percentile (22.7% vs 0%; P = 0.01) and a non-significant increase in the proportion of fetuses with UA-PI > 95th percentile (11.4% vs 0%; P = 0.12) during fetal surgery. None of the fetuses showed absent or reversed end-diastolic velocity in the UA or absent or reversed DV a-wave at any stage during OSB repair. All abnormal Doppler parameters returned to normal after surgery. CONCLUSIONS: During open fetal surgery for OSB repair, a small hysterotomy, reduced fetal manipulation and maintenance of a normal amniotic fluid volume seem to prevent severe fetal Doppler abnormalities. The mild Doppler changes observed during fetal surgery could be a manifestation of fetal adaptation to the stress of fetal surgery. © 2020 International Society of Ultrasound in Obstetrics and Gynecology.


Assuntos
Espinha Bífida Cística/cirurgia , Adulto , Líquido Amniótico , Velocidade do Fluxo Sanguíneo , Feminino , Idade Gestacional , Humanos , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Artéria Cerebral Média/diagnóstico por imagem , Gravidez , Estudos Prospectivos , Fluxo Pulsátil , Resultado do Tratamento , Ultrassonografia Doppler , Artérias Umbilicais/diagnóstico por imagem , Adulto Jovem
13.
Nanomaterials (Basel) ; 10(6)2020 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-32545858

RESUMO

In this paper we report on the influence of polysaccharides' molecular structure on the antibacterial activity and cytotoxicity of composites based on silver nanoparticles (AgNPs) immobilized into carboxymethyl-cellulose (CMC). These composites were green synthesized from the reduction of silver ions into aqueous solutions of the polysaccharide, using CMC with different degree of substitution (DS) and molecular weight (Mw). The composites were characterized by transmission electron microscopy (TEM), as well as infrared (ATR-FTIR), ultraviolet (UV-Vis), Raman, and X-ray photo-electron (XPS) spectroscopic techniques. The antibacterial activity was evaluated with minimum inhibitory concentration against Enterococcus faecalis. The cytotoxicity of composites was assessed against human gingival fibroblast. Experimental evidence suggests that particle size distribution and morphology of AgNPs change according to the quantity of silver precursor added to the reaction, as well as the DS and Mw of CMC used for composites preparation. This is related to the dispersion of silver precursor into aqueous solutions of the polysaccharide and the formation of Ag-O coordination bonds among AgNPs and COO- moieties of CMC. Moreover, these coordination bonds modify the ability of nanoparticles to produce and release Ag+ into aqueous dispersion, adjusting their antibacterial activity and the induction of cytotoxicity into the tested biological environments.

14.
Ultrasound Obstet Gynecol ; 56(4): 516-521, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32068928

RESUMO

OBJECTIVE: To evaluate the impact of fetal endoscopic tracheal occlusion (FETO) on improving survival of fetuses with severe left-sided congenital diaphragmatic hernia (CDH), as compared with contemporaneous cases managed expectantly during pregnancy, in a country with suboptimal neonatal management. METHODS: In this prospective cohort study, consecutive fetuses with isolated left-sided CDH, normal karyotype and severe pulmonary hypoplasia (defined as liver herniation and observed/expected lung-to-head circumference ratio below 26%) were selected for FETO at less than 32 weeks of gestation in a single tertiary referral center in Queretaro, Mexico. Postnatal outcome (survival up to 28 days after birth) was compared between fetuses treated with FETO and contemporaneous cases with similar lung size managed expectantly during pregnancy. RESULTS: Twenty-five fetuses with isolated severe left-sided CDH treated with FETO were matched individually with 25 cases managed expectantly during pregnancy. Endotracheal placement of the balloon was performed successfully on the first attempt in all cases. The median gestational age (GA) at balloon placement was 29.1 (range, 25.6-31.8) weeks and 34.1 (range, 30.0-36.1) weeks at balloon removal. There were no technical problems with the introduction or removal of the balloon in any cases. The median GA at delivery was significantly lower in the group treated with FETO than in those managed expectantly (35.3 vs 37.7 weeks; P = 0.04). The survival rate was significantly higher in the group treated with FETO than in those without fetal intervention (32% vs 0%; P < 0.001). CONCLUSION: In settings with suboptimal neonatal management, FETO was associated with improved neonatal survival in fetuses with isolated left-sided CDH and severe pulmonary hypoplasia. Copyright © 2020 ISUOG. Published by John Wiley & Sons Ltd.


Resultado de supervivencia en una hernia diafragmática congénita grave del lado izquierdo, con y sin oclusión traqueal endoscópica fetal en un país con un tratamiento neonatal subóptimo OBJETIVO: Evaluar el impacto de la oclusión traqueal endoscópica fetal (OTEF) en la mejora de la supervivencia de los fetos con hernia diafragmática congénita (HDC) grave del lado izquierdo, en comparación con los casos actuales tratados como embarazo gestante, en un país con un tratamiento neonatal subóptimo. MÉTODOS: En este estudio prospectivo de cohortes, se seleccionaron fetos consecutivos con HDC aislada del lado izquierdo, cariotipo normal e hipoplasia pulmonar grave (definida como hernia hepática y una proporción observada/esperada de la circunferencia pulmonar-cabeza inferior al 26%) para una OTEF antes de las 32 semanas de gestación, en un único centro de medicina especializada terciaria en Querétaro (México). El resultado postnatal (supervivencia hasta los 28 días después del nacimiento) se comparó entre fetos tratados con OTEF y los casos contemporáneos con tamaño pulmonar similar, tratados como embarazo gestante. RESULTADOS: Veinticinco fetos con HDC grave aislada del lado izquierdo que habían sido tratados con OTEF fueron emparejados individualmente con 25 casos tratados como embarazo gestante. La colocación endotraqueal del globo se realizó con éxito en el primer intento en todos los casos. La mediana de la edad gestacional (EG) en el momento de la colocación del globo fue de 29,1 (rango, 25,6-31,8) semanas y 34,1 (rango, 30,0-36,1) semanas cuando se retiró el globo. En ningún caso hubo problemas técnicos con la introducción o la retirada del globo. La mediana de la EG en el momento del parto fue significativamente menor en el grupo tratado con OTEF que en el grupo tratado como gestante (35,3 vs 37,7 semanas; P=0,04). La tasa de supervivencia fue significativamente más alta en el grupo tratado con OTEF que en los casos sin intervención fetal (32% vs 0%; P<0,001). CONCLUSIÓN: En los entornos con un tratamiento neonatal subóptimo, la OTEF se asoció con una mejora de la supervivencia neonatal en los fetos con HDC aislada del lado izquierdo y con hipoplasia pulmonar grave. Copyright © 2020 ISUOG. Published by John Wiley & Sons Ltd.


Assuntos
Oclusão com Balão/mortalidade , Fetoscopia/mortalidade , Hérnias Diafragmáticas Congênitas/cirurgia , Pulmão/anormalidades , Traqueia/cirurgia , Oclusão com Balão/métodos , Cefalometria , Feminino , Fetoscopia/métodos , Feto/diagnóstico por imagem , Feto/embriologia , Feto/cirurgia , Hérnias Diafragmáticas Congênitas/embriologia , Humanos , Recém-Nascido , Pulmão/embriologia , México , Gravidez , Cuidado Pré-Natal/estatística & dados numéricos , Estudos Prospectivos , Taxa de Sobrevida , Traqueia/embriologia , Resultado do Tratamento , Ultrassonografia Pré-Natal , Conduta Expectante/estatística & dados numéricos
15.
Carbohydr Polym ; 200: 289-296, 2018 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-30177169

RESUMO

In this paper, the synthesis of magnetic nanofibrous materials with a soft ferromagnetic response based on magnetite nanoparticles (SMON) loaded to aqueous carboxymethyl-cellulose (CMC)/polyvinyl-alcohol (PVA) polymeric blends is reported. The nanofibrous materials were obtained from the electrospinning of SMON-CMC/PVA blends with different SMON content, applying a constant tension of 15 kV. The synthesized samples were analyzed by transmission electron microscopy, scanning electron microscopy, attenuated total reflectance Fourier transform infrared, Raman and X-Ray photoelectron spectroscopy, as well as static magnetic measuring. Our experimental findings indicate that nanofibers' diameter decreases as SMON content in the electrospun polymeric blends is increased, since these magnetic nanoparticles diminish the interactions between PVA and CMC molecules, which improves their spinnability. Moreover, the spatial distribution of SMON in the fibers provides to the synthesized nanofibrous materials a novel soft ferromagnetic response at room temperature. This phenomenon is attributed to the formation of nanoparticles' aggregates that are discretely distributed in the nanofibers.

16.
Eur J Pain ; 22(1): 114-126, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28845556

RESUMO

BACKGROUND: The objective of this study was to estimate the association between sleep quality (SQ) and improvements in low back pain (LBP) and disability, among patients treated for LBP in routine practice. METHODS: This prospective cohort study included 461 subacute and chronic LBP patients treated in 11 specialized centres, 14 primary care centres and eight physical therapy practices across 12 Spanish regions. LBP, leg pain, disability, catastrophizing, depression and SQ were assessed through validated questionnaires upon recruitment and 3 months later. Logistic regression models were developed to assess: (1) the association between the baseline score for SQ and improvements in LBP and disability at 3 months, and (2) the association between improvement in SQ and improvements in LBP and disability during the follow-up period. RESULTS: Seventy-three per cent of patients were subacute. Median scores at baseline were four points for both pain and disability, as assessed with a visual analog scale and the Roland-Morris Questionnaire, respectively. Regression models showed (OR [95% CI]) that baseline SQ was not associated with improvements in LBP (0.99 [0.94; 1.06]) or in disability (0.99 [0.93; 1.05]), although associations existed between 'improvement in SQ' and 'improvement in LBP' (4.34 [2.21; 8.51]), and 'improvement in SQ' and 'improvement in disability' (4.60 [2.29; 9.27]). CONCLUSIONS: Improvement in SQ is associated with improvements in LBP and in disability at 3-month follow-up, suggesting that they may reflect or be influenced by common factors. However, baseline SQ does not predict improvements in pain or disability. SIGNIFICANCE: In clinical practice, sleep quality, low back pain and disability are associated. However, sleep quality at baseline does not predict improvement in pain and disability.


Assuntos
Pessoas com Deficiência , Dor Lombar/fisiopatologia , Sono/fisiologia , Adulto , Idoso , Catastrofização/complicações , Catastrofização/fisiopatologia , Depressão/complicações , Depressão/fisiopatologia , Feminino , Humanos , Dor Lombar/complicações , Masculino , Pessoa de Meia-Idade , Medição da Dor , Atenção Primária à Saúde , Estudos Prospectivos , Inquéritos e Questionários , Adulto Jovem
17.
Ultrasound Obstet Gynecol ; 49(6): 744-750, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27363854

RESUMO

OBJECTIVE: To assess the effectiveness of laser surgery in fetuses with a cystic lung lesion with systemic arterial blood supply (hybrid lung lesion) at risk of perinatal death. METHODS: A cohort of five consecutive fetuses with a large hybrid lung lesion associated with hydrops and/or pleural effusion with severe lung compression was selected for percutaneous ultrasound-guided fetal laser ablation of the feeding artery (FLAFA) before 32 weeks' gestation in a single tertiary national referral center in Queretaro, Mexico. The primary outcomes were survival and need for postnatal surgery. RESULTS: FLAFA was performed successfully in all cases at a median gestational age of 24.9 (range, 24.4-31.7) weeks. After fetal intervention, dimensions in both lungs increased and fluid effusions resolved in all cases. All cases were delivered liveborn at term at a median gestational age of 39.6 (range, 38.0-39.7) weeks, without respiratory morbidity or need for oxygen support, resulting in perinatal survival of 100%. During follow-up, three (60%) cases showed progressive regression of the entire lung mass and did not require postnatal surgery, whereas in two (40%) cases a progressive decrease in size of the mass was observed but a cystic portion of the lung mass persisted and postnatal lobectomy was required. CONCLUSION: In fetuses with large hybrid lung lesions at risk of perinatal death, FLAFA is feasible and could improve survival and decrease the need for postnatal surgery. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.


Assuntos
Malformação Adenomatoide Cística Congênita do Pulmão/cirurgia , Doenças Fetais/cirurgia , Pneumopatias/diagnóstico , Artérias/cirurgia , Estudos de Coortes , Malformação Adenomatoide Cística Congênita do Pulmão/complicações , Malformação Adenomatoide Cística Congênita do Pulmão/diagnóstico por imagem , Malformação Adenomatoide Cística Congênita do Pulmão/fisiopatologia , Feminino , Doenças Fetais/diagnóstico por imagem , Doenças Fetais/fisiopatologia , Terapias Fetais , Idade Gestacional , Humanos , Terapia a Laser , Pneumopatias/complicações , Pneumopatias/congênito , Pneumopatias/diagnóstico por imagem , Pneumopatias/fisiopatologia , Pneumopatias/cirurgia , México , Gravidez , Estudos Prospectivos , Resultado do Tratamento , Ultrassonografia de Intervenção , Ultrassonografia Pré-Natal
19.
Carbohydr Polym ; 136: 46-53, 2016 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-26572327

RESUMO

In this contribution a novel green chemistry approach for the synthesis of nanofibrous materials based on blends of carboxymethyl-cellulose (CMC)-silver nanoparticles (AgNPs) composite and polyvinyl-alcohol (PVA) is proposed. These nanofibrous materials were obtained from the electrospinning of blends of aqueous solutions of CMC-AgNPs composite and PVA, which were prepared at different CMC/PVA weight ratios in order to electrospin nanofibers applying a constant tension of 15kV. The synthesized materials were characterized by means of transmission electron microscopy, scanning electron microscopy; as well as Fourier-transform infrared, ultraviolet and Raman spectroscopic techniques. Experimental evidence suggests that the diameter of the nanofibers is thinner than any other reported in the literature regarding the electrospinning of CMC. This feature is related to the interactions of AgNPs with carboxyl functional groups of the CMC, which diminish those between the later and acetyl groups of PVA.


Assuntos
Carboximetilcelulose Sódica/química , Química Verde , Nanofibras/química , Nanotecnologia , Prata/química , Técnicas de Química Sintética , Nanopartículas Metálicas/química , Modelos Moleculares , Conformação Molecular , Álcool de Polivinil/química
20.
Radiología (Madr., Ed. impr.) ; 56(3): 257-267, mayo-jun. 2014. ilus, tab
Artigo em Espanhol | IBECS | ID: ibc-122451

RESUMO

La atelectasia pulmonar es un indicador importante de una enfermedad subyacente, potencialmente grave, que es imprescindible diagnosticar precozmente. Uno de los mecanismos más frecuentes es la reabsorción de aire distal a la obstrucción de las vías respiratorias. La radiografía de tórax es una herramienta excelente para diagnosticarla, especialmente útil para descartar obstrucciones bronquiales centrales (por ejemplo, una neoplasia endobronquial). Si no se reconocen correctamente los signos de la pérdida de volumen el diagnóstico y el tratamiento pueden retrasarse. En este artículo se describen los principales hallazgos radiográficos de la atelectasia pulmonar lobular y su correlación con la tomografía computarizada. Se incluyen los signos clásicos descritos en la bibliografía y otros menos conocidos y a su vez sutiles (AU)


Atelectasis is an important indicator of potentially severe underlying disease that must be diagnosed as early as possible. One of the most common mechanisms is the reabsorption of air distal to respiratory tract obstruction. The chest X-ray is an excellent tool to diagnose atelectasis, and it is especially useful for ruling out central bronchial obstructions (e.g., from endobronchial tumors). If the signs of volume loss are not recognized correctly, the diagnosis and treatment can be delayed. This article describes the main findings of lobar atelectasis on chest X-rays and their correlations with CT findings, including the classic signs described in the literature and other, less known and sometimes subtle signs (AU)


Assuntos
Humanos , Atelectasia Pulmonar , Radiografia Torácica/métodos , Tomografia Computadorizada por Raios X/métodos , Diagnóstico Precoce , Fatores de Risco , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...